Rental License Lookup

What city rental inspectors check: a checklist built from city inspection lists

We read the published rental inspection checklists of cities in Minnesota and Iowa. Here are the items that show up again and again, where cities differ (screens, egress, extinguishers, alarm age), and the most common failures Bloomington reports.

By the Rental License Lookup deskPublished November 21, 2026Not legal advice
A home inspector in high visibility vest examines an electrical outlet in a modern room.
Photo: RDNE Stock project on Pexels

Most cities that inspect rentals publish the list their inspectors work from. We read the published checklists from cities on this site, mostly in Minnesota and Iowa. Fewer than ten items appear on almost every list. Around them, the lists disagree on specific numbers that a landlord can easily get wrong. Use this page to prepare, and always read your own city's checklist, which is linked from its city page.

The items nearly every list includes

  • Smoke alarms in every bedroom, outside sleeping areas and on every level, including the basement. Rochester and Moorhead also want alarms less than 10 years old, and Moorhead asks for the manufacture date written on the front.
  • Carbon monoxide alarms near sleeping rooms. Most Minnesota lists say within 10 feet, matching state law. Cedar Rapids says within 15 feet of sleeping areas where there are fuel-burning appliances or an attached garage.
  • Egress windows in every bedroom that open fully and meet a minimum size. Basement bedrooms are the common problem.
  • Deadbolts on entry doors. Bloomington and Duluth both specify a 1-inch throw. Bloomington and Richfield don't allow a deadbolt that needs a key to open from inside.
  • Handrails and guards. Handrails on stairs with four or more risers and guards where a drop is more than 30 inches. Saint Paul, Brooklyn Park, Coon Rapids and Sioux City spell this out.
  • Heat that can hold 68 degrees, the figure on the Minneapolis, Saint Paul and Marshall lists.
  • Electrical basics. Panels labeled and reachable, outlet covers in place, no extension cords used as permanent wiring, and GFCI outlets near water. Winona, Moorhead and Sioux City list GFCIs.
  • Dryer vents run outside in metal. Plastic or vinyl is a failure in Burnsville, Richfield and Des Moines.
  • House numbers at least 4 inches tall and readable from the street. Saint Paul, Duluth, Burnsville and Cedar Rapids say so, and Cedar Rapids wants them on alley-facing garages too.

Where the lists disagree

ItemWhat different cities require
Window screensRochester: June 1 to October 15, and year-round on grade-level windows. Duluth: full screens May 15 to October 15. Brooklyn Park: May 15 to October 15. Des Moines: tight-fitting 16-mesh screens on openable windows.
Fire extinguishersWinona: at least 2A 10BC, serviced every year. Moorhead: one 2A10BC (5 lb), tagged every 12 months. Cedar Rapids: at least 1A10BC in every single-family rental and every unit. Many other lists don't mention them.
Battery smoke alarmsCedar Rapids requires 10-year lithium batteries in battery-only alarms. Rochester and Moorhead say hardwired alarms must be replaced with hardwired ones.
Window locksMinneapolis: windows within 24 feet of grade. Saint Paul: up to and including the second story. Rochester and Duluth: within 6 feet of the ground. Richfield: first-floor windows.
Hot waterSaint Paul: water heater between 120 and 130 degrees. Bloomington: hot water at least 110 degrees.
Heating checksMinneapolis requires a safety check every two years for heating systems older than 10 years. Moorhead wants the system serviced within the past 24 months. Richfield may require a heating contractor's certification for furnaces over 15 years old.
Ceiling heightDuluth doesn't allow basement rooms with ceilings under 6 feet 4 inches, and attic bedrooms need 6 feet 8 inches.

The most common failures

Bloomington publishes the items its inspectors cite most: missing or dead smoke and CO alarms, missing outlet covers, gas burners that don't light on their own, and missing latch-type deadbolts. Any of these can be fixed in an afternoon, which is why it pays to walk the house with the list a week before the inspector does.

Outside and around the property

Inspections often go beyond the building. Brooklyn Park requires each home to have its own weekly garbage service, and Coon Rapids wants grass under 8 inches. Both, along with Bloomington, set rules for where vehicles may be parked. Saint Paul requires lidded garbage containers and parking on paved surfaces only.

Who has to be there

  • Rochester allows only the owner or manager of record to escort the inspector.
  • Crystal requires the owner or a designated manager to notify tenants and be present, and corrections are due within 30 days.
  • Duluth inspects every unit in a rental building, including one the owner lives in.

Your city's list

Each city page links to that city's own checklist where one is published, under "What the city's own checklist looks for." Start with Minneapolis, Saint Paul, Rochester, Des Moines or Cedar Rapids, or find your city. The state alarm laws behind the alarm items are in our smoke and CO alarm guide.

Sources

  1. Minneapolis: Rental Property Checklist (PDF)
  2. Saint Paul: Residential pre-inspection checklist (PDF)
  3. Rochester: Rental property pre-inspection checklist (PDF)
  4. Duluth: Residential pre-inspection checklist (PDF)
  5. Bloomington: Rental housing licensing and inspection (pre-inspection checklist)
  6. Brooklyn Park: Rental property inspections
  7. Burnsville: Sample inspection checklist
  8. Winona: Rental inspection checklist
  9. Richfield: Common rental housing corrections (PDF)
  10. Moorhead: Common code checklist 2025 (PDF)
  11. Coon Rapids: Rental inspection checklist (PDF)
  12. Maplewood: Rental property inspection checklist (PDF)
  13. Des Moines: Rental inspection checklist (PDF)
  14. Cedar Rapids: Rental inspection checklist, revised March 17, 2025 (PDF)
  15. Sioux City: Rental inspection checklist (PDF)
  16. Marshall: Rental self-inspection form (PDF)
  17. Crystal: Rental licensing guide (PDF)
  18. Iowa Code § 10A.518 (smoke and CO alarms)

Sources checked November 21, 2026. General information, not legal advice.